Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image RemovedImage Added


DocumentDocument RequirementsUpload RequirementsExamples
Anchor
verificationofInclinometer verificationofInclinometer Articulated Dump Trucks only- Verification of Inclinometer integrated with tipping function
  • Articulated Dump Trucks only- Verification of Inclinometer integrated with tipping function.
tenyearinspection
tenyearinspection
10 Year Major inspection certification
  • NOTE: Major Inspection records are also required to be stored with plant item on site
  • Completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 10 years from the date the crane was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances

Issue/inspection Date = Record this as it is listed on the recertification

Expiry Date = recertification date + 10 years
Anchor
sixyearinspection
sixyearinspection
6 Year Major inspection certification
  • NOTE: Major Inspection records are also required to be stored with plant item on site
  • Completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 6 years from the date the crane was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances

Issue/inspection Date = Record this as it is listed on the

certificate Lighting Plants - electrical

recertification

Expiry Date = recertification date + 6 years

Access equipment – electrical/RCD

Anchor
accessequipmentelectrical
accessequipmentelectrical

  • Report to be on company letterhead
  • Company completing report to provide details including:
    • ABN
    • Contact including address and phone
    • Report to be current – ie date on report within 3 months of current date

Issue/inspection Date = Record this as it is listed on the certificate

Expiry Date = Record this as issue date + 3 months.
Access equipment - MEWP inspection

For all MEWP both < and > 11 metres:

  • Report to be on company letterhead
  • Company completing report to provide details including:
    • ABN
    • Contact including address and phone
  • Report to be current – ie date on report within 12 months of current date

For MEWP > 11 metres:

  • Copy of user SafeWork NSW (or equivalent) high risk work licence
  • Copy of plant SafeWork NSW (or equivalent) high risk work registration

Issue/inspection Date = Record this as it is listed on the certificate

Expiry Date = Record this as issue date +
3 months. No non-compliances
12 months.
Anchor
verificationofInclinometer
verificationofInclinometer
Articulated Dump Trucks only- Verification of Inclinometer integrated with tipping function
  • Evidence must be uploaded for Articulated Dump Trucks only
  • Evidence must show verification of Inclinometer integrated with tipping function.

Issue/inspection Date = Record this as it is listed on the uploaded  evidence


Anchor
cranesafegreenstickerreport
cranesafegreenstickerreport
Cranes and Lifting – annual recertification
  • Must be CraneSafe certificate
  • Owner name on certificate to match the company registering asset
  • Duration as per certificate
  • Black and white or colour (green) acceptable
  • Only front of certificate needs to be shown when certificate is uploaded.

Issue/inspection Date = Record this as it is listed on the certificate

Expiry Date = Record this as it is listed on the certificate 
 Cranes and Lifting – >10 year recertification
  • Completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 10 years from the date the crane was first commissioned/ registered or reregistered whichever was first.
  • Anchor
    pipewallthickness
    pipewallthickness
    Concrete pumps - monthly pipe wall thickness testing records
    • Must be completed in Concrete Pumping Association logbook

    Issue/inspection Date = Record this as it is listed in the logbook

    Expiry Date = Record this as issue date + 1 month.
    Anchor
    liftfreelysuspendedload
    liftfreelysuspendedload
    EM Plant used to lift freely suspended loads - Verification of lift rating chart, anti hose burst protection and rated lift point.
    • Evidence must be uploaded for EM Plant used to lift freely suspended loads
    • Evidence must show Verification of lift rating chart, anti hose burst protection and rated lift point.
    Issue/inspection Date = Record this as it is listed on the
    recertificationExpiry Date = recertification date + 10 years Access equipment - MEWP inspection

    For all MEWP both < and > 11 metres:

    • Report to be on company letterhead
    • Company completing report to provide details including:
      • ABN
      • Contact including address and phone
    • Report to be current – ie date on report within 12 months of current date

    For MEWP > 11 metres:

  • Copy of user SafeWork NSW (or equivalent) high risk work licence
  • Copy of plant SafeWork NSW (or equivalent) high risk work registration

    Access equipment – electrical/RCD

    Anchoraccessequipmentelectricalaccessequipmentelectrical
    uploaded  evidence
    Anchor
    excavquickhitch
    excavquickhitch
    Excavators fitted with Quick Hitches- Supply verification of Fully Auto Hitch
    • Evidence must be uploaded for Excavators fitted with Quick Hitches
    • Evidence needs to verify Fully Auto Hitch
    Issue/inspection Date = Record this as it is listed on the uploaded  evidence
    Anchor
    liftingequipmentregister
    liftingequipmentregister
    Lifting Equipment Register

    NOTE: Lifting Equipment Register to be available with Plant Item performing lifting tasks.

    Issue/inspection Date = Record this as it is listed on the certificate

    Expiry Date = Record this as issue date + 12 months.

     

    Lighting Plants - electrical
    • Report to be on company letterhead
    • Company completing report to provide details including:
      • ABN
      • Contact including address and phone
      • Report to be current – ie date on report within 3 months of current date.

    Issue/inspection Date = Record this as it is listed on the certificate
    Expiry Date = Record this as issue date + 3 months.

     
    Anchor
    dynamiclmisystem
    dynamiclmisystem
    Pick and carry cranes only - Verification of Dynamic LMI system installed
    • Evidence supplied must be Verification of Dynamic LMI system installed
    • Date of installation to be indicated on
    evidence
    • eviden
    • Issue/inspection Date = Record this as the Installation Date shown on  uploaded evidence
     

    Piling Rigs – crack testing report

    Anchor
    pilesafegreensticker
    pilesafegreensticker

    • Company issuing report must be accredited by either:
    • To be on company letterhead signed and stamped.  
    • Owner name on certificate to match the company registering asset
    • Duration as per certificate
    • Black and white or colour (green) acceptable
    • Only front of certificate needs to be shown when certificate is uploaded.
    • Issue/inspection Date = Record this as it is listed on the certificate
    • Expiry Date = Record this as issue date + 12 months.
     
    Piling Rigs – lifting equipment register
    • Issue/inspection Date = Record this as it is listed on the certificate
    • Expiry Date = Record this as issue date + 12 months.
     Must be completed in Concrete Pumping Association logbook
    Anchor
    pipewallthicknesspipewallthicknessConcrete pumps - monthly pipe wall thickness testing records
    ndttesting
    ndttesting
    Record of NDT Testing / Annual Inspection
    • NOTE: Inspection records are also required to be stored with plant item on site
    • Asset details to be displayed on evidence (Type and Model)
    • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
    • Date of inspection at least 1 year from the date the asset was first commissioned/ registered or reregistered whichever was first.
    • No non-compliances
    • Issue/inspection Date = Record this as it is listed in the
    logbook
    • log book
    • Expiry Date = 12 months from last annual inspection record.

    Anchor
    truckmountedewp
    truckmountedewp
    Truck Mounted EWP- 6 Month Weight test
    • Evidence supplied must be for truck mounted EWP weight test
    • Bi-Annual Inspection required
    • Date of installation to be test on evidence
    • Issue/inspection Date = Record this as it is listed on The certificate
    • Expiry Date = Record this as issue date +
    1 month. 
    • 6 months.

    Truck Mounted EWP- HV Insulated 6 Month Electrical Test
    • Evidence supplied must be for truck mounted EWP HV Insulated electrical test
    • Bi-Annual Inspection required
    • Date of installation to be test on evidence

    Issue/inspection Date = Record this as it is listed on the certificate

    Expiry Date = Record this as issue date + 6 months.

    Vehicle Mounted Cranes and Crane Trucks – annual recertification
    • Must be CraneSafe certificate
    • Owner name on certificate to match the company registering asset
    • Duration as per certificate
    • Black and white or colour (green) acceptable
    • Only front of certificate needs to be shown when certificate is uploaded

    Issue/inspection Date = Record this as it is listed on the certificate

    Expiry Date = Record this as it is listed on the certificate
     
    Vehicle Mounted Cranes and Crane Trucks – crane log book
    • Must be CraneSafe log book
    • Owner name in log book to match the company registering asset
    • Duration – from first date entered into logbook.

    Issue/inspection Date = Record this as it is listed in the log book