DocumentDocument RequirementsUpload RequirementsExamples
Anchor
tenyearinspection
tenyearinspection
10 Year Major inspection certification
  • NOTE: Major Inspection records are also required to be stored with plant item on site
  • Completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 10 years from the date the crane was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances

Issue/inspection Date = Record this as it is listed on the recertification

Expiry Date = recertification date + 10 years
 
Anchor
sixyearinspection
sixyearinspection
6 Year Major inspection certification
  • NOTE: Major Inspection records are also required to be stored with plant item on site
  • Completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 6 years from the date the crane was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances

Issue/inspection Date = Record this as it is listed on the recertification

Expiry Date = recertification date + 6 years
 

Access equipment – electrical/RCD

Anchor
accessequipmentelectrical
accessequipmentelectrical

  • Report to be on company letterhead
  • Company completing report to provide details including:
    • ABN
    • Contact including address and phone
    • Report to be current – ie date on report within 3 months of current date

Issue/inspection Date = Record this as it is listed on the certificate

Expiry Date = Record this as issue date + 3 months.
 
Access equipment - MEWP inspection

For all MEWP both < and > 11 metres:

  • Report to be on company letterhead
  • Company completing report to provide details including:
    • ABN
    • Contact including address and phone
  • Report to be current – ie date on report within 12 months of current date

For MEWP > 11 metres:

  • Copy of user SafeWork NSW (or equivalent) high risk work licence
  • Copy of plant SafeWork NSW (or equivalent) high risk work registration

Issue/inspection Date = Record this as it is listed on the certificate

Expiry Date = Record this as issue date + 12 months.
 
Anchor
verificationofInclinometer
verificationofInclinometer
Articulated Dump Trucks only- Verification of Inclinometer integrated with tipping function
  • Evidence must be uploaded for Articulated Dump Trucks only
  • Evidence must show verification of Inclinometer integrated with tipping function.

Issue/inspection Date = Record this as it is listed on the uploaded  evidence

 


Anchor
cranesafegreenstickerreport
cranesafegreenstickerreport
Cranes and Lifting – annual recertification
  • Must be CraneSafe certificate
  • Owner name on certificate to match the company registering asset
  • Duration as per certificate
  • Black and white or colour (green) acceptable
  • Only front of certificate needs to be shown when certificate is uploaded.

Issue/inspection Date = Record this as it is listed on the certificate

Expiry Date = Record this as it is listed on the certificate 
 
Anchor
pipewallthickness
pipewallthickness
Concrete pumps - monthly pipe wall thickness testing records
  • Must be completed in Concrete Pumping Association logbook

Issue/inspection Date = Record this as it is listed in the logbook

Expiry Date = Record this as issue date + 1 month.
 
Anchor
liftfreelysuspendedload
liftfreelysuspendedload
EM Plant used to lift freely suspended loads - Verification of lift rating chart, anti hose burst protection and rated lift point.
  • Evidence must be uploaded for EM Plant used to lift freely suspended loads
  • Evidence must show Verification of lift rating chart, anti hose burst protection and rated lift point.
Issue/inspection Date = Record this as it is listed on the uploaded  evidence
 

Anchor
excavquickhitch
excavquickhitch
Excavators fitted with Quick Hitches- Supply verification of Fully Auto Hitch
  • Evidence must be uploaded for Excavators fitted with Quick Hitches
  • Evidence needs to verify Fully Auto Hitch
Issue/inspection Date = Record this as it is listed on the uploaded  evidence
 

Anchor
liftingequipmentregister
liftingequipmentregister
Lifting Equipment Register
Evidence supplied must be

NOTE: Lifting Equipment Register

  • Date of installation to be indicated on evidence
  • to be available with Plant Item performing lifting tasks.

    Issue/inspection Date = Record this as

    the Installation Date shown on  uploaded evidence 

    it is listed on the certificate

    Expiry Date = Record this as issue date + 12 months.


    Lighting Plants - electrical
    • Report to be on company letterhead
    • Company completing report to provide details including:
      • ABN
      • Contact including address and phone
      • Report to be current – ie date on report within 3 months of current date.

    Issue/inspection Date = Record this as it is listed on the certificate
    Expiry Date = Record this as issue date + 3 months.

     
    Anchor
    dynamiclmisystem
    dynamiclmisystem
    Pick and carry cranes only - Verification of Dynamic LMI system installed
    • Evidence supplied must be Verification of Dynamic LMI system installed
    • Date of installation to be indicated on eviden
    • Issue/inspection Date = Record this as the Installation Date shown on  uploaded evidence
     

    Piling Rigs – crack testing report

    Anchor
    pilesafegreensticker
    pilesafegreensticker

    • Company issuing report must be accredited by either:
    • To be on company letterhead signed and stamped.  
    • Owner name on certificate to match the company registering asset
    • Duration as per certificate
    • Black and white or colour (green) acceptable
    • Only front of certificate needs to be shown when certificate is uploaded.
    • Issue/inspection Date = Record this as it is listed on the certificate
    • Expiry Date = Record this as issue date + 12 months.
     
    Piling Rigs – lifting equipment register
    • Issue/inspection Date = Record this as it is listed on the certificate
    • Expiry Date = Record this as issue date + 12 months.
     
    Anchor
    ndttesting
    ndttesting
    Record of NDT Testing
    at
    / Annual Inspection
    • Evidence supplied must be NDT Testing at Annual Inspection
    • Date of installation to be indicated on evidence
    • NOTE: Inspection records are also required to be stored with plant item on site
    • Asset details to be displayed on evidence (Type and Model)
    • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
    • Date of inspection at least 1 year from the date the asset was first commissioned/ registered or reregistered whichever was first.
    • No non-compliances
    • Issue/inspection Date = Record this as it is listed
    on
    • in the
    certificate
    • log book
    • Expiry Date =
    Record this as issue date +
    • 12 months from last annual inspection record.
     

    Anchor
    truckmountedewp
    truckmountedewp
    Truck Mounted EWP- 6 Month Weight test
    • Evidence supplied must be for truck mounted EWP weight test
    • Bi-Annual Inspection required
    • Date of installation to be test on evidence
    • Issue/inspection Date = Record this as it is listed on
    the
    • The certificate
    • Expiry Date = Record this as issue date + 6 months.
     

    Truck Mounted EWP- HV Insulated 6 Month Electrical Test
    • Evidence supplied must be for truck mounted EWP HV Insulated electrical test
    • Bi-Annual Inspection required
    • Date of installation to be test on evidence

    Issue/inspection Date = Record this as it is listed on the certificate

    Expiry Date = Record this as issue date + 6 months.
     

    Vehicle Mounted Cranes and Crane Trucks – annual recertification
    • Must be CraneSafe certificate
    • Owner name on certificate to match the company registering asset
    • Duration as per certificate
    • Black and white or colour (green) acceptable
    • Only front of certificate needs to be shown when certificate is uploaded

    Issue/inspection Date = Record this as it is listed on the certificate

    Expiry Date = Record this as it is listed on the certificate
     
    Vehicle Mounted Cranes and Crane Trucks – crane log book
    • Must be CraneSafe log book
    • Owner name in log book to match the company registering asset
    • Duration – from first date entered into logbook.

    Issue/inspection Date = Record this as it is listed in the log book