Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image RemovedImage Added


DocumentDocument RequirementsUpload RequirementsExamples

Anchor
logbook
logbook
Logbook

NOTE: Company doesn’t need to upload entire document as log book must be stored with plant item.               

  • Photo of front page of log book needs to be uploaded and example of recent checks.
  • Asset details to be displayed on evidence (Type and Model)
  • Owner name in log book to match the company owning the item of plant i.e. if the plant is hired in then the owner will be the hire company which will be different to the user/operator.                                                                     
  • Log book should be plant specific & supplied via recognised source.
  • Issue/inspection Date = Record this as it is listed in the log book
  • Expiry Date = None

Anchor
mechanicalfitterquals
mechanicalfitterquals
Plant Mechanic/Fitter Qualifications

  • Name on uploaded evidence to match the Mechanic's name on the Maintenance Report or Service Record
  • Recognised Training Institution name to be displayed on document
  • International trade qualifications are not accepted
  • Black and white or colour copy of evidence is accepted

Accepted Forms of Evidence:

  • Certificate of Proficiency
  • Certificate of Competency
  • Certificate III
  • Trade / Tradesperson / Tradesman/ Craft / Craftsman Certificate
  • Certificate of completion of apprenticeship

Accepted Course Codes / Tiles:

  • Plant Mechanic
  • Fitter / Fitting
  • Fitting & Turning
  • Engineering - Mechanical
  • Engineering Fabrication
  • Fitting & Welding
  • Mechanical
  • Metal Fabrication
  • Vehicle Mechanic


  • Issue Date =Date of completion shown on the evidence (Only required to be entered if shown)
  • Expiry Date = To be recorded as the same expiry date as the maintenance / service record

Anchor
quickhitch
quickhitch
Quick Hitch Compliance Documentation

NOTE: Hitch certification details to be stored with plant item.

  • Asset details to be displayed on evidence (Type and Model)
  • Evidence must be uploaded for Excavators fitted with Quick Hitches
  • Evidence needs to verify Fully
Auto Hitch
  • Automated Quick Hitch (Semi-automatic Hitches not permitted without prior written approval from Lendlease)
  • Issue/inspection Date = Record this as it is listed on the uploaded  evidence
  • Expiry Date = None

Anchor
liftingequipreg

 

liftingequipreg
Current Lifting Equipment Register 

NOTE: Lifting Equipment Register to be available with Plant Item performing lifting tasks.

  • Asset details to be displayed on evidence (Type and Model)
  • Company issuing report must be accredited by either:
 JAS

Image AddedImage Added

  • Issue/inspection Date = Record this as it is listed on the certificate
  • Expiry Date = Record this as issue date + 12 months.
 

Anchor
monthlypipelinethickness
monthlypipelinethickness
Monthly Pipeline Thickness Report

NOTE: Reports need to be stored with the pump
  • Must be recorded in readable / understandable format that ties in with plant item.
  • Report will indicate that the wall thickness test has been conducted, including the date and who conducted the test
  • Single wall pipes to have thickness tests available
  • Twin wall pipes cannot be thickness tested so volume of concrete pumped through them must be recorded with upper limits detailed.
  • Twin wall pipes to have volumes recorded.
  • Issue/inspection Date = Record this as it is listed in the logbook
  • Expiry Date = One off upload. Doesn’t expire
 


Anchor
cranesafe
cranesafe
Crane Safe Green Sticker Inspection

NOTE: Crane Safe Sticker to be located on Plant Item.

  • Asset details to be displayed on evidence (Type and Model)
  • Must be CraneSafe certificate
  • Owner name on certificate to match the company owning the asset.
  • Duration as per expiry on certificate
  • Black and white or colour (green) acceptable
  • Only front of certificate needs to be shown when certificate is uploaded.
  • Issue/inspection Date = Record this as it is listed on the certificate
  • Expiry Date = Record this as it is listed on the certificate 

Anchor
pilesafe
pilesafe
Pile Safe Green Sticker Inspection

NOTE: Pile Safe Sticker to be located on Plant Item.

  • Asset details to be displayed on evidence (Type and Model)
  • Must be Pile Safe certificate
  • Owner name on certificate to match the company owning the asset.
  • Duration as per expiry on certificate
  • Black and white or colour (green) acceptable
  • Only front of certificate needs to be shown when certificate is uploaded.
  • Issue/inspection Date = Record this as it is listed on the certificate
  • Expiry Date = Record this as it is listed on the certificate 
 

Anchor
3monthlyinspection
3monthlyinspection
3 Monthly Inspection

TBATBA

Anchor
annualinspection
annualinspection
Annual Inspection

NOTE: Inspection record to be stored with plant item.
  • Asset details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • In most cases, evidence of competent person will be provided in the form of qualifications such as a diesel mechanic or mechanic. A letter from a business stating that all of their mechanics have qualifications is acceptable.
  • Date of inspection at least 1 year from the date the asset was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances
  • Issue/inspection Date = Record this as it is listed in the log book
  • Expiry Date = 12 months from last annual inspection record.

Anchor
tenyearinspect
 
tenyearinspect
10 Year Major Inspection (Cranes & EWP's)

NOTE: Inspection record to be stored with plant item.

  • Asset details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • In most cases, evidence of competent person will be provided in the form of qualifications such as a diesel mechanic or mechanic. A letter from a business stating that all of their mechanics have qualifications is acceptable.
  • Date of inspection at least 10 years from the date the asset was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances.
  • Cranes not to be older than 20 years
  • Issue/inspection Date = Record this as it is listed on the recertification
  • Expiry Date = recertification date + 10 years

Anchor

 

sixyearinspect
sixyearinspect

6 Year

Major Inspection (Concrete Pumps)

NOTE: Inspection record to be stored with plant item.

  • Asset details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 6 years from the date the asset was first commissioned/ registered or reregistered whichever was first.
  • No non-compliances
  • Issue/inspection Date = Record this as it is listed on the recertification
  • Expiry Date = recertification date + 6 years
 

Anchor
weedandseed
weedandseed
Weed and Seed Inspection Declaration

NOTE: Inspection record to be stored with plant item.

  • Asset details to be displayed on evidence (Type and Model)
  • Must be completed by a person who is competent to conduct inspections
  • Inspection form to indicate that all parts of the plant item have been cleaned
  • Issue Date = Date of inspection
  • Expiry Date = TBA

Anchor
earthingstakeevidence
earthingstakeevidence
Earthing Stake Evidence

TBATBA

Anchor
sondrecords
sondrecords
S.O.N.D. (Sonar Operational Nav Device) Calibration Records

TBATBA

Anchor
testtagrcdevidence
testtagrcdevidence
Test & Tag and RCD Evidence

TBATBA

Anchor
uppercabhours
uppercabhours
Upper Cab Hours

TBATBA
Lift/Tie Down CertificationNOTE: Required for any lift/tie down that is not OEM.
  • Certification record to be stored with plant item
  • Asset details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 1 year from the date the asset was first commissioned/registered/re-registered (whichever was first)
  • Issue Date = As per certification
  • Expiry Date = 12 months from issue date

List of OperatorsNOTE: Pegasus Administrators to check the profiles of each operator listed and confirm that they have the required Statement of Attainment competency that matches the plant item.
  • Evidence must be a list of operators who will be operating the plant item on site
  • All operators listed must be qualified to operate the specified plant item
  • Proof of operator training must be supplied (this is a mandatory requirement for all plant competencies)
  • Issue Date = Date of plant submission
  • Expiry Date = 1 year from issue date

Load ChartsNOTE: Evidence to be supplied if required by OEM.
  • Load charts to be stored with plant item
  • Asset details to be displayed on evidence (Type and Model)
  • Must list lifting point locations and their rated capacity
  • If applicable, must list boom configuration and the maximum load that can be lifted for each lifting point and boom configuration
  • If applicable, must list stabiliser requirements
  • If applicable, must list deductions for attachments (e.g. a bucket or quick-hitch devices)
  • Issue Date = None
  • Expiry Date = None